GENERAL
DATA
Output
Nominal Power 1000 W adjustable
Operating
band 87.5 ÷ 108 MHz
Direct to
channel Yes
RS232/RS485
Yes. Connector DB9 Female
Points of
measure RF Sample - MPX Monitor
Displayed
Parameters More than 50 parameters displayed on a wide
graphic
OLED
Adjustments
From the frontal panel through OLED/from PC
Number of
L-DMOS in amplifier stage 2
RF power
stage technology ICEFET & ECOSAVING
Dimensions:
Rack units 2U
Dimensions:
W - H - D 48.5 - 8.5 - 58.5 cm / 19.11 - 3.35 - 23.05 inches
Weight 13.2
Kg / 29.1 lbs
Number of
cooling fans 3
CONNECTORS
RF Output
connector 7/16" DIN Female
MPX
Connector BNC Female balanced, unbalanced
LEFT &
RIGHT Connectors (or Mono) XLR Female
AES/EBU
Connector XLR Female/optical
AUX
Connectors BNC Female
RDS BNC
Female
SCA BNC
Female
ETHERNET
RJ45
19 kHz
monitor BNC Female
MPX monitor
BNC Female
10 MHz
IN/OUT SMA
PPS IN/OUT
SMA
GPS ANTENNA
SMA
RF
PERFORMANCE
Output
impedance 50 Ω
Automatic
power RF control Stabilizes the output power value on the set value
Overall
output power RF stability +/- 0,1 dB
VSWR 2:1 at
full power.
Automatic
power reduction beyond 1.7:1.
Transmitter
is protected from both open and short
circuit
conditions.
Harmonics
< -85 dBc
Out of band
emission (spurious) < -85 dBc
AUDIO
PERFORMANCE
MPX input
level +15/-10 dBu for 75 KHz standard deviation
MPX input
impedance Selectable 5 K unbalanced, 600Ω balanced
L/R input
level +15/-10 dBu for 75 KHz standard deviation
L/R input
impedance Selectable 10 K - 600 Ω, balanced
AES/EBU
Electric and optical input
AES/EBU
input resolution 24 bits
AES/EBU
input sample rate 32,44.1,48,96,192 KHz automatically selected
AES/EBU
input level -20 dBFS - 0 dBFS
AES/EBU
input impedance 110 Ω balanced
SCA/RDS
input level 0 dBu for 10% deviation
Pilot
amplitude adjustment Soft adjust 0.05% steps from front panel
Pilot phase
adjustment Soft adjust 0.01 degree steps from front panel
Pilot tone
frequency 19 KHz
Pilot tone
deviation Soft adjust +/- 7.5 KHz
Pilot tone
frequency stability +/-1 Hz
THD+N (Mpx
operation) < 0.01% or better with 75 KHz frequency deviation
< 0.01%
or better with 100 KHz frequency deviation
30 Hz to 15
KHz
THD+N
(Stereo/Mono operation) < 0.03% or better with 75 KHz frequency deviation
< 0.03%
or better with 100 KHz frequency deviation
30 Hz to 15
kHz
Pre-emphasis
0/25/50/75 microseconds selectable
Pre-emphasis
tolerance +/- 0.1 dB
FM S/N (Mpx
operation) 85 dB
20 Hz to 23
KHz @ 53 KHz - detector RMS
FM S/N CCIR
(Stereo/Mono operation) > 80 dB weighted
> 80 dB
unweighted
@ 400 Hz,
75 KHz frequency deviation,
quasi-peak
detector, 50 us de-emphasis
Asynchronous
AM S/N unweighted > 60 dB
@ 400 Hz,
75 us de-emphasis
Synchronous
AM S/N > 50 dB
@ 400 Hz,
75 us de-emphasis
Amplitude-frequency
characteristic
(Mpx
operation)
+/- 0.1 dB
(without pre-emphasis)
20 Hz to
100 kHz @ 400 Hz
Amplitude
frequency characteristic
(Stereo/Mono
operation)
+/- 0.1 dB
(without pre-emphasis)
+/- 0.2 dB
(with pre-emphasis)
20 Hz to 15
kHz @ 400 Hz
Stereo
separation > 70 dB
20 Hz to 15
KHz
Linear
crosstalk > 70 dB
20 Hz to 15
kHz
Intermodulation
distortion <0.05% Measured with two of tones
1 kHz &
1.3 KHz, ratio
1:1 at 100%
modulation
Class of
emission F3
Stereo
emission According to ITU-R reccomendation
450 (pilot
tone)
EXCITER
PERFORMANCE
Frequency
deviation +/- 75 KHz 0.1 dB steps adjustable
Maximum
frequency deviation +/- 150 KHz
Frequency
stability +/- 0.1ppm with oven
RF
frequency steps 1 Hz
Phase Response
+/- 0.1 degree from linear phase
20 Hz to
100 KHz
Internal
sample rate 2.4 GHz
Oven 10 MHz
Yes internal, aging +/- 0.1ppm year
GPS Yes
internal
SFN Yes,
with delay from 0 to 1s, step 100ns
INSTALLATION
REQUIREMENTS
Power
supply 230 Singlephase Version 50-60 Hz VAC
Power
consumption (typical) 1430 W
Current
drain (typical @230V) 6.2 A
Overall
efficiency
(typical
from -3dB to Pnom)
> = 70%
Power
factor > 0.95
Fuses and
circuit breakers n.2 fuses 25 A BT311325 OMEGA
COOLING/NOISE/DATA
Cooling
system Forced air-cooling
Acoustic
noise < 65 phon
@
transmitter room, 2 m distance
of the
front of transmitter
Air outlet
420 m3/h
ENVIRONMENT
Temperature
range (operating) -5 ÷ +45 °C, 23 ÷ 113 °F
Temperature
range (non operating) -20 ÷ +55 °C, -4 ÷ 131 °F
Humidity
range (operating) 95% @ 40 °C, 104 °F
Humidity
range (non operating) 90% @ 55 °C, 131 °F
Altitude
range (operating) <3000 meters / <9840 Feet
Altitude
range (non operating) <15000 meters / < 49200 Feet
TELECONTROL
& TELEMETRY
Remote
control Yes
Remote
control, dry contacts Yes
SNMP option
Yes (external)